MLD AND MLD SNOOPING COMMANDS
IPV
6 MLD LAST-MEMBER-QUERY-INTERVAL
ipv6 mld last-member-query-interval
Overview Use this command to configure the interval at which the router sends MLD
group-specific host query messages.
Use the no variant of this command to set this frequency to the default.
Syntax
ipv6 mld last-member-query-interval <milliseconds>
no ipv6 mld last-member-query-interval
Default 1000 milliseconds
Mode Interface Configuration for a specified VLAN interface or a range of VLAN
interfaces.
Example The following example changes the MLD group-specific host query message
interval to 2 seconds:
awplus# configure terminal
awplus(config)# ipv6 forwarding
awplus(config)# ipv6 multicast-routing
awplus(config)# interface vlan2
awplus(config-if)# ipv6 enable
awplus(config-if)# ipv6 mld last-member-query-interval 2000
Related
Commands
ipv6 mld immediate-leave
Parameter Description
<milliseconds> The time delay between successive query messages (in
milliseconds). Valid values are from 1000 to 25500 milliseconds.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals