EasyManua.ls Logo

Allied Telesis AlliedWare Plus - Show Stack Indicator

Allied Telesis AlliedWare Plus
3082 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C613-50100-01 REV C Command Reference for x930 Series 2445
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
VIRTUAL CHASSIS STACKING (VCSTACK™) COMMANDS
SHOW
STACK INDICATOR
show stack indicator
Overview This command enables you to physically identify a specific stack member. This
command will flash the Master Status LED for the stack member specified. The
pattern will be a number of flashes in quick succession followed by a longer pause;
where the number of flashes equals the stack member ID.
Syntax
show stack indicator [<stack-member>|all] [timeout
<timeout-period>]
Mode User Exec and Privileged Exec
Examples To find stack member 2 by flashing its Master Status LED, use the command:
awplus# show stack indicator 2
To find stack member 2 by flashing its Master Status LED for 1 minute, use the
command:
awplus# show stack indicator 2 timeout 60
Parameter Description
<stack-member> The ID of the stack member to be identified (1-8).
Default is All.
all Will flash the Master Status LED on each stack member with
its own appropriate ID pattern.
<timeout-period> The time period (in seconds) that the indication will display.
Default is 30 seconds.