C613-50100-01 REV C Command Reference for x930 Series 527
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
VLAN COMMANDS
SWITCHPORT
ENABLE VLAN
switchport enable vlan
Overview This command enables the VLAN on the port manually once disabled by certain
actions, such as QSP (QoS Storm Protection) or EPSR (Ethernet Protection
Switching Ring). Note that if the VID is not given, all disabled VLANs are re-enabled.
Syntax
switchport enable vlan [<1-4094>]
Mode Interface Configuration
Example To re-enable the port1.0.1 from VLAN 1:
awplus# configure terminal
awplus(config)# interface port1.0.1
awplus(config-if)# switchport enable vlan 1
Related
Commands
show mls qos interface storm-status
storm-window
Parameter Description
vlan Re-enables the VLAN on the port.
<1-4094> VLAN ID.