EasyManua.ls Logo

Allied Telesis AlliedWare Plus - Clear Test Interface

Allied Telesis AlliedWare Plus
3082 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C613-50100-01 REV C Command Reference for x930 Series 438
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
INTERFACE TESTING COMMANDS
CLEAR
TEST INTERFACE
clear test interface
Overview This command clears test results and counters after issuing a test interface
command. Test results and counters must be cleared to issue subsequent test
interface commands later on.
Syntax
clear test interface {<port-list>|all}
Mode Privileged Exec
Examples To clear the counters for port1.0.1 use the command:
awplus# clear test interface port1.0.1
To clear the counters for all interfaces use the command:
awplus# clear test interface all
Related
Commands
test interface
Parameter Description
<port-list> The ports to test. A port-list can be:
a switch port (e.g. port1.0.6)
a continuous range of ports separated by a hyphen, e.g.
port1.0.1-port1.0.6
a comma-separated list of the above, e.g.
port1.0.1,port1.0.5-1.0.6
The specified ports must exist.
all All interfaces