Page #2886 background imageLoading...
Page #2886 background image
C613-50100-01 REV C Command Reference for x930 Series 2886
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
LLDP COMMANDS
LLDP
REINIT
lldp reinit
Overview This command sets the value of the reinitialization delay. This is the minimum time
after disabling LLDP on a port before it can reinitialize.
The no variant of this command sets the reinitialization delay back to its default
setting.
Syntax
lldp reinit <1-10>
no lldp reinit
Default The default reinitialization delay is 2 seconds.
Mode Global Configuration
Examples To set the reinitialization delay to 3 seconds, use the commands:
awplus# configure terminal
awplus(config)# lldp reinit 3
To set the reinitialization delay back to its default, use the commands:
awplus# configure terminal
awplus(config)# no lldp reinit
Related
Commands
show lldp
Parameter Description
<1-10> The delay in seconds.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications