EasyManuals Logo

Allied Telesis AlliedWare Plus User Manual

Allied Telesis AlliedWare Plus
3082 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #697 background imageLoading...
Page #697 background image
C613-50100-01 REV C Command Reference for x930 Series 697
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
GVRP COMMANDS
GVRP
TIMER
gvrp timer
Overview Use this command to set GVRP timers in Interface Configuration mode for a given
interface.
Use the no variant of this command to reset the GVRP timers to the defaults
specified in the table below.
Syntax
gvrp timer {join <timer-value>|leave <timer-value>|leaveall
<timer-value>}
no gvrp timer {join|leave|leaveall}
Mode Interface Configuration
Defaults The default join time value is 20 centiseconds (200 milliseconds), the default leave
timer value is 60 centiseconds (600 milliseconds), and the default leaveall timer
value is 1000 centiseconds (10,000 milliseconds).
Usage When configuring the leave timer, set it to more than or equal to three times the
join timer value. The settings for the leave and join timers must be the same
for all GVRP enabled switches. See also the section “Setting the GVRP Timers” in the
GVRP Feature Overview and Configuration Guide.
Use the show gvrp timer command to confirm GVRP timers set with this command.
Examples To set the GVRP join timer to 30 hundredths of a second (300 milliseconds) for
interface port1.0.1, enter the commands:
awplus# configure terminal
awplus(config)# interface port1.0.1
awplus(config-if)# gvrp timer join 30
To set the GVRP leave timer to 90 hundredths of a second (900 milliseconds) for
interface port1.0.1, enter the commands:
awplus# configure terminal
awplus(config)# interface port1.0.1
awplus(config-if)# gvrp timer leave 90
Parameter Description
join Specifies the timer for joining the group (default is 20
centiseconds / hundredths of a second, or 200 milliseconds).
leave Specifies the timer for leaving a group (default is 60 centiseconds /
hundredths of a second, or 600 milliseconds).
leaveall Specifies the timer for leaving all groups (default is 1000
centiseconds / hundredths of a second, or 10,000 milliseconds).
<timer-value> <1-65535> The timer value in hundredths of a second
(centiseconds).

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals