C613-50100-01 REV C Command Reference for x930 Series 1095
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
OSPFV3 FOR IPV6 COMMANDS
IPV
6 OSPF DEAD-INTERVAL
ipv6 ospf dead-interval
Overview This command sets the interval during which no hello packets are received and
after which a neighbor is declared dead.
The dead-interval is the amount of time that OSPF waits to receive an OSPF hello
packet from the neighbor before declaring the neighbor is down. This value is
advertised in the router’s hello packets. It must be a multiple of the hello-interval
and be the same for all routers on a specific network.
The no variant of this command returns the interval to the default of 40 seconds.
Syntax
ipv6 ospf dead-interval <1-65535> [<inst-id>]
no ipv6 ospf dead-interval
Mode Interface Configuration for a VLAN interface.
Example The following example shows configuring the dead-interval to 10 seconds on the
VLAN interface vlan2:
awplus# configure terminal
awplus(config)# interface vlan2
awplus(config-if)# ipv6 ospf dead-interval 10
Related
Commands
ipv6 ospf hello-interval
show ipv6 ospf interface
Parameter Description
<1-65535> The interval in seconds.
Default: 40
<inst-id> The instance ID
Default: 0

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals