C613-50100-01 REV C Command Reference for x930 Series 341
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
LOGGING COMMANDS
LOG
BUFFERED
log buffered
Overview This command configures the device to store log messages in RAM. Messages
stored in RAM are not retained on the device over a restart. Once the buffered log
reaches its configured maximum allowable size old messages will be deleted to
make way for new ones.
Syntax
log buffered
no log buffered
Default The buffered log is configured by default.
Mode Global Configuration
Examples To configured the device to store log messages in RAM use the following
commands:
awplus# configure terminal
awplus(config)# log buffered
To configure the device to not store log messages in a RAM buffer use the
following commands:
awplus# configure terminal
awplus(config)# no log buffered
Related
Commands
clear log buffered
default log buffered
log buffered (filter)
log buffered size
log buffered exclude
show log
show log config

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals