TRIGGER COMMANDS
TYPE
PERIODIC
type periodic
Overview This command configures a trigger to be activated at regular intervals. The time
period between activations is specified in minutes.
Syntax
type periodic <1-1440>
Mode Trigger Configuration
Usage A combined limit of 10 triggers of the type periodic and time can be configured. If
you attempt to add more than 10 triggers the following error message is displayed:
For an example trigger configuration that uses the type periodic command, see
“See Daily Statistics” in the Triggers Feature Overview and Configuration Guide.
Example To configure trigger 44 to activate periodically at 10 minute intervals use the
following commands:
awplus# configure terminal
awplus(config)# trigger 44
awplus(config-trigger)# type periodic 10
Related
Commands
show trigger
trigger
Parameter Description
<1-1440> The number of minutes between activations.
% Cannot configure more than 10 triggers with the type time or
periodic

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals