ALLIED TELESIS MANAGEMENT FRAMEWORK™ (AMF) COMMANDS
ERASE
FACTORY-DEFAULT
erase factory-default
Overview This command erases all data from NVS and all data from flash excluding the
following:
The current release file and its /flash/.release file
The backup release file and /flash/.backup file
v1 license files /flash/.configs/.swfeature.lic
v2 license files /flash/.configs/.sw_v2.lic
The device is then rebooted and returns the device to its factory default condition.
The device can then be used for automatic node recovery.
Syntax
erase factory-default
Mode Global Configuration.
Usage This command is an alias to the atmf cleanup command.
Example To erase data, use the command:
Node_1(config)# erase factory-default
This command will erase all NVS, all flash contents except for
the boot release, and any license files, and then reboot the
switch. Continue? (y/n):y
Related
Commands
atmf cleanup

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals