C613-50100-01 REV C Command Reference for x930 Series 3060
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
PING-POLLING COMMANDS
TIMEOUT
(PING POLLING)
timeout (ping polling)
Overview This command specifies the time in seconds that the polling instance waits for a
response to a ping packet. You may find a higher time-out useful in networks
where ping packets have a low priority.
The no variant of this command resets the set time out to the default of one
second.
Syntax
timeout <1-30>
no timeout
Default The default is 1 second.
Mode Ping-Polling Configuration
Examples To specify the timeout as 5 seconds for ping-poll instance 43, use the commands:
awplus# configure terminal
awplus(config)# ping-poll 43
awplus(config-ping-poll)# timeout 5
To reset the timeout to its default of 1 second for ping-poll instance 43, use the
commands:
awplus# configure terminal
awplus(config)# ping-poll 43
awplus(config-ping-poll)# no timeout
Related
Commands
critical-interval
fail-count
normal-interval
ping-poll
sample-size
show ping-poll
up-count
Parameter Description
<1-30> Length of time, in seconds, that the polling instance waits for a
response from the polled device.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals