C613-50100-01 REV C Command Reference for x930 Series 2169
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
AUTHENTICATION COMMANDS
AUTH
-WEB-SERVER PING-POLL FAILCOUNT
auth-web-server ping-poll failcount
Overview This command sets a fail count for the ping polling feature when used with
Web-Authentication. The failcount parameter specifies the number of
unanswered pings. A supplicant (client device) is logged off when the number of
unanswered pings are greater than the failcount set with this command.
Use the no variant of this command to resets the fail count for the ping polling
feature to the default (5 pings).
Syntax
auth-web-server ping-poll failcount <1-100>
no auth-web-server ping-poll failcount
Default The default failcount for ping polling is 5 pings.
Mode Global Configuration
Examples To set the failcount of ping polling to 10 pings, use the following commands:
awplus# configure terminal
awplus(config)# auth-web-server ping-poll failcount 10
To set the failcount of ping polling to default, use the following commands:
awplus# configure terminal
awplus(config)# no auth-web-server ping-poll failcount
Validation
Commands
show auth
show auth-web-server
show running-config
Parameter Description
<1-100> Count.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals