C613-50100-01 REV C Command Reference for x930 Series 1738
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
PIM-SM COMMANDS
IP
PIM REGISTER-SUPPRESSION
ip pim register-suppression
Overview Use this command to configure the register-suppression time, in seconds,
overriding the default of 60 seconds. Configuring this value modifies
register-suppression time at the DR. Configuring this value at the RP modifies the
RP-keepalive-period value if the ip pim rp-register-kat command is not used.
Use the no variant of this command to reset the value to its default of 60 seconds.
Syntax
ip pim register-suppression <1-65535>
no ip pim register-suppression
Mode Global Configuration
Example
awplus# configure terminal
awplus(config)# ip pim register-suppression 192
Parameter Description
<1-65535> Register suppression on time in seconds.