C613-50100-01 REV C Command Reference for x930 Series 2850
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
SNMP COMMANDS
SNMP
-SERVER ENABLE TRAP
snmp-server enable trap
Overview Use this command to enable the switch to transmit the specified notifications
(traps).
Note that the Environmental Monitoring traps defined in the AT-ENVMONv2-MIB
are enabled by default.
Use the no variant of this command to disable the transmission of the specified
notifications.
Syntax
snmp-server enable trap {[atmf] [atmflink] [atmfnode] [atmfrr]
[auth] [bgp] [dhcpsnooping] [epsr] [lldp] [loopprot] [mstp]
[nsm] [ospf] [pim] [power-inline] [qsp] [rmon] [thrash-limit]
[vcs] [vrrp]}
no snmp-server enable trap {[atmf] [atmflink] [atmfnode]
[atmfrr] [auth] [bgp] [dhcpsnooping] [epsr] [lldp] [loopprot]
[mstp] [nsm] [ospf] [pim] [power-inline] [qsp] [rmon]
[thrash-limit] [vcs] [vrrp]}
Parameter Description
atmf AMF traps.
atmflink AMF Link traps.
atmfnode AMF Node traps.
atmfrr AMF Reboot Rolling traps.
auth Authentication failure.
bgp BGP traps.
dhcpsnooping DHCP snooping and ARP security traps. These notifications must
also be set using the ip dhcp snooping violation command,
and/or the arp security violation command.
epsr EPSR traps.
lldp Link Layer Discovery Protocol (LLDP) traps. These notifications
must also be enabled using the lldp notifications command,
and/or the lldp med-notifications command.
loopprot Loop Protection traps.
mstp MSTP traps.
nsm NSM traps.
ospf OSPF traps.
pim PIM traps.
power-inline Power-inline traps (Power Ethernet MIB RFC 3621).
qsp QoS Storm Protection
rmon RMON traps.