C613-50100-01 REV C Command Reference for x930 Series 306
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
PLUGGABLES AND CABLING COMMANDS
FIBER
-MONITORING ACTION
fiber-monitoring action
Overview Use this command to specify an action to be taken if the optical power received on
the port changes from the baseline by the amount specified in the
fiber-monitoring sensitivity command.
Use the no variant of this command to remove the specified action or all actions
from the port.
Syntax
fiber-monitoring action {trap|shutdown}
no fiber-monitoring action [trap|shutdown]
Default By default a log message is generated, but no additional action is performed.
Mode Interface Configuration mode for a fiber port.
Usage If fiber monitoring is enabled and this command is not used to set an action, a
change in received power on a fiber port only generates a log message.
Example To set the device to send an SNMP notification when ports 1.0.1 or 1.0.2 receive
reduced power, use the commands:
awplus(config)# interface port1.0.1-1.0.2
awplus(config-if)# fiber-monitoring action trap
To set the device to send an SNMP notification and to shut down the port when
ports 1.0.1 or 1.0.2 receive reduced power, use the commands:
awplus(config)# interface port1.0.1-1.0.2
awplus(config-if)# fiber-monitoring action trap shutdown
To set the device not to send an SNMP notification when ports 1.0.1 or 1.0.2 receive
reduced power, use the commands:
awplus(config)# interface port1.0.1-1.0.2
awplus(config-if)# no fiber-monitoring action trap
To set the device not to perform any action when it receives reduced power on
ports 1.0.1 or 1.0.2, use the commands:
awplus(config)# interface port1.0.1-1.0.2
awplus(config-if)# no fiber-monitoring action
Related
Commands
fiber-monitoring sensitivity
show system fiber-monitoring
Parameter Description
trap Send an SNMP notification.
shutdown Shutdown the port.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals