ip pim rp-register-kat
Overview Use this command to configure the Keep Alive Time (KAT) for (S,G) states at the RP
(Rendezvous Point) to monitor PIM-SM Register packets.
Use the no variant of this command to return the PIM-SM KAT timer to its default
value of 210 seconds.
Syntax
ip pim rp-register-kat <1-65535>
no ip pim rp-register-kat
Mode Global Configuration
Default The default PIM-SM KAT timer value is 210 seconds.
Examples
awplus# configure terminal
awplus(config)# ip pim rp-register-kat 3454
awplus# configure terminal
awplus(config)# no ip pim rp-register-kat
Related
Commands
ip pim rp-address
ip pim rp-candidate
Parameter Description
<1-65536> Specify the KAT timer in seconds. The default value is 210 seconds.