Overview This command (configured to the stack) initiates the action of a pre-configured
trigger to occur when the stack enters the fail-over state.
Syntax
type stack master-fail
Mode Trigger Configuration
Example To configure trigger 86 to activate when stack master fail-over event occurs, use
the commands:
awplus# configure terminal
awplus(config)# trigger 86
awplus(config-trigger)# type stack master-fail
Related
Commands
stack disabled-master-monitoring
trigger
type stack disabled-master
type stack member
type stack link