C613-50100-01 REV C Command Reference for x930 Series 906
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
RIP COMMANDS
RIP
RESTART GRACE-PERIOD
rip restart grace-period
Overview Use this command to change the grace period of RIP graceful restart.
Use the no variant of this command to disable this function.
Syntax
rip restart grace-period <1-65535>
no rip restart grace-period <1-65535>
Mode Global Configuration
Default The default RIP grace-period is 60 seconds.
Usage Use this command to enable the Graceful Restart feature on the RIP process.
Entering this command configures a grace period for RIP.
When a master failover happens on a VCStack, the RIP grace-period will be the
longest period between the default value (60 seconds is the default RIP
grace-period) and the configured RIP grace-period value from this command. So
the configured RIP grace-period value will not be used for a VCStack master
failover if it is shorter than the default RIP grace-period value.
Example
awplus# configure terminal
awplus(config)# rip restart grace-period 200

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals