C613-50100-01 REV C Command Reference for x930 Series 906
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
RIP COMMANDS
RIP
RESTART GRACE-PERIOD
rip restart grace-period
Overview Use this command to change the grace period of RIP graceful restart.
Use the no variant of this command to disable this function.
Syntax
rip restart grace-period <1-65535>
no rip restart grace-period <1-65535>
Mode Global Configuration
Default The default RIP grace-period is 60 seconds.
Usage Use this command to enable the Graceful Restart feature on the RIP process.
Entering this command configures a grace period for RIP.
When a master failover happens on a VCStack, the RIP grace-period will be the
longest period between the default value (60 seconds is the default RIP
grace-period) and the configured RIP grace-period value from this command. So
the configured RIP grace-period value will not be used for a VCStack master
failover if it is shorter than the default RIP grace-period value.
Example
awplus# configure terminal
awplus(config)# rip restart grace-period 200