C613-50100-01 REV C Command Reference for x930 Series 336
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
LOGGING COMMANDS
DEFAULT
LOG CONSOLE
default log console
Overview This command restores the default settings for log messages sent to the terminal
when a log console command is issued. By default all messages are sent to the
console when a log console command is issued.
Syntax
default log console
Mode Global Configuration
Example To restore the log console to its default settings use the following commands:
awplus# configure terminal
awplus(config)# default log console
Related
Commands
log console
log console (filter)
log console exclude
show log config