C613-50100-01 REV C Command Reference for x930 Series 3070
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
SFLOW COMMANDS
SFLOW
COLLECTOR MAX-DATAGRAM-SIZE
sflow collector max-datagram-size
Overview This command sets the maximum size of the sFlow® datagrams sent to the
collector.
The no variant of this command resets the maximum-datagram-size to the default.
Syntax
sflow collector max-datagram-size <200-1500>
no sflow collector max-datagram-size
Default 1400 bytes
Mode Global Configuration
Example To set the maximum datagram size to 1200, use the command:
awplus# configure terminal
awplus(config)# sflow collector max-datagram-size 1200
Related
Commands
show running-config sflow
show sflow
Parameter Description
<200-1500> The maximum number of bytes that can be sent in an sFlow
datagram sent from the agent to the collector.