C613-50100-01 REV C Command Reference for x930 Series 338
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
LOGGING COMMANDS
DEFAULT
LOG HOST
default log host
Overview This command restores the default settings for log sent to a remote syslog server.
By default no filters are defined for remote syslog servers. Filters must be defined
before messages will be sent. This command also restores the remote syslog server
time offset value to local (no offset).
Syntax
default log host <ip-addr>
Mode Global Configuration
Example To restore the default settings for messages sent to the remote syslog server with
IP address 10.32.16.21 use the following commands:
awplus# configure terminal
awplus(config)# default log host 10.32.16.21
Related
Commands
log host
log host (filter)
log host exclude
log host source
log host time
show log config
Parameter Description
<ip-addr> The IP address of a remote syslog server

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals