EasyManuals Logo

Allied Telesis AlliedWare Plus User Manual

Allied Telesis AlliedWare Plus
3082 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2875 background imageLoading...
Page #2875 background image
C613-50100-01 REV C Command Reference for x930 Series 2875
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
LLDP COMMANDS
LLDP
FASTSTART-COUNT
lldp faststart-count
Overview Use this command to set the fast start count for LLDP-MED. The fast start count
determines how many fast start advertisements LLDP sends from a port when it
starts sending LLDP-MED advertisements from the port, for instance, when it
detects a new LLDP-MED capable device.
The no variant of this command resets the LLDPD-MED fast start count to the
default (3).
Syntax
lldp faststart-count <1-10>
no lldp faststart-count
Default The default fast start count is 3.
Mode Global Configuration
Examples To set the fast start count to 5, use the command:
awplus# configure terminal
awplus(config)# lldp faststart-count 5
To reset the fast start count to the default setting (3), use the command:
awplus# configure terminal
awplus(config)# no lldp faststart-count
Related
Commands
show lldp
Parameter Description
<1-10> The number of fast start advertisements to send.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals