C613-50100-01 REV C Command Reference for x930 Series 3029
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
TRIGGER COMMANDS
TYPE
PING-POLL
type ping-poll
Overview This command configures a trigger that activates when Ping Polling identifies that
a target device’s status has changed. This allows you to run a configuration script
when a device becomes reachable or unreachable.
Syntax
type ping-poll <1-100> {up|down}
Mode Trigger Configuration
Example To configure trigger 106 to activate when ping poll 12 detects that its target
device is now unreachable, use the following commands:
awplus# configure terminal
awplus(config)# trigger 106
awplus(config-trigger)# type ping-poll 12 down
Related
Commands
show trigger
trigger
Parameter Description
<1-100> The ping poll ID.
up The trigger activates when ping polling detects that the target is
reachable.
down The trigger activates when ping polling detects that the target is
unreachable.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals