C613-50100-01 REV C Command Reference for x930 Series 673
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
POWER OVER ETHERNET COMMANDS
POWER
-INLINE RPS BOOST
power-inline rps boost
Overview Use this command to configure the power boost feature. When this feature is
enabled, a PoE switch with two power supplies uses the PoE power from both
supplies, to increase its available power budget.
The no variant of this command disables this feature.
Syntax
power-inline rps boost [member <1-8>]
no power-inline rps boost [member <1-8>]
Default The power boost feature is disabled by default.
Mode Global Configuration
Usage The power boost feature determines whether a PoE switch with two power
supplies has an increased power budget or has redundant PoE power. When the
power boost feature is enabled, a PoE switch with two power supplies actively uses
the PoE power from both supplies to increase its available power budget. When
the feature is disabled, the switch uses the PoE power of only one of its power
supplies and keeps the other in reserve in case the primary power supply should
fail or lose power.
As an example, assume that a PoE switch has one AT-PWR1200 power supply,
which has a power budget of 740W for powered devices. Thus, the switch would
have a total power budget of 740W. Now assume the switch has two AT-PWR1200
power supplies. When the power boost mode is enabled, the switch uses the PoE
power from both supplies, for a total power budget of 1480W. When the power
boost mode is disabled, the switch has an active PoE power of 740W and a
redundant budget of the same amount. The switch activates the redundant power
budget only if the power supply providing the active power budget fails or loses
power.
Examples To configure boosted power for all stack members, use the following commands:
awplus# configure terminal
awplus(config)# power-inline rps boost
To configure boosted power for stack member 1, use the following commands:
awplus# configure terminal
awplus(config)# power-inline rps boost member 1
Parameter Description
member The VCStack member if the switch is in a VCStack.
<1-8> Specifies the VCStack member ID in the range <1-8>.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals