C613-50100-01 REV C Command Reference for x930 Series 998
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
OSPF COMMANDS
IP
OSPF RESYNC-TIMEOUT
ip ospf resync-timeout
Overview Use this command to set the interval after which adjacency is reset if out-of-band
resynchronization has not occurred. The interval period starts from the time a
restart signal is received from a neighbor.
Use the no variant of this command to return to the default.
Syntax
ip ospf [<ip-address>] resync-timeout <1-65535>
no ip ospf [<ip-address>] resync-timeout
Mode Interface Configuration for a VLAN interface.
Example The following example shows setting the OSPF resynchronization timeout value to
65 seconds on the VLAN interface vlan2.
awplus# configure terminal
awplus(config)# interface vlan2
awplus(config-if)# ip ospf resync-timeout 65
Parameter Description
<ip-address> The IP address of the interface.
<1-65535> Specifies the resynchronization timeout value of the interface in
seconds.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals