C613-50100-01 REV C Command Reference for x930 Series 998
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
OSPF COMMANDS
IP
OSPF RESYNC-TIMEOUT
ip ospf resync-timeout
Overview Use this command to set the interval after which adjacency is reset if out-of-band
resynchronization has not occurred. The interval period starts from the time a
restart signal is received from a neighbor.
Use the no variant of this command to return to the default.
Syntax
ip ospf [<ip-address>] resync-timeout <1-65535>
no ip ospf [<ip-address>] resync-timeout
Mode Interface Configuration for a VLAN interface.
Example The following example shows setting the OSPF resynchronization timeout value to
65 seconds on the VLAN interface vlan2.
awplus# configure terminal
awplus(config)# interface vlan2
awplus(config-if)# ip ospf resync-timeout 65
Parameter Description
<ip-address> The IP address of the interface.
<1-65535> Specifies the resynchronization timeout value of the interface in
seconds.