RIP COMMANDS
RESTART
RIP GRACEFUL
restart rip graceful
Overview Use this command to force the RIP process to restart, and optionally set the
grace-period.
Syntax
restart rip graceful [grace-period <1-65535>]
Mode Privileged Exec
Default The default RIP grace-period is 60 seconds.
Usage After this command is executed, the RIP process immediately shuts down. It
notifies the system that RIP has performed a graceful shutdown. Routes that have
been installed into the route table by RIP are preserved until the specified
grace-period expires.
When a restart rip graceful command is issued, the RIP configuration is reloaded
from the last saved configuration. Ensure you first enter the command copy
running-config startup-config.
When a master failover happens on a VCStack, the RIP grace-period will apply the
larger value of either the setting's configured value, or its default of 60 seconds.
Example To apply a restart rip graceful setting, grace-period to 100 seconds use the
following commands:
awplus# copy running-config startup-config
awplus# restart rip graceful grace-period 100

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals