EasyManuals Logo

Allied Telesis AlliedWare Plus User Manual

Allied Telesis AlliedWare Plus
3082 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3048 background imageLoading...
Page #3048 background image
C613-50100-01 REV C Command Reference for x930 Series 3048
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
PING-POLLING COMMANDS
NORMAL
-INTERVAL
normal-interval
Overview This command specifies the time period between pings when the device is
reachable.
The no variant of this command resets the time period to the default of 30 seconds.
Syntax
normal-interval <1-65536>
no normal-interval
Default The default is 30 seconds.
Mode Ping-Polling Configuration
Examples To specify a time period of 60 seconds between pings when the device is reachable
for ping-poll instance 45, use the commands:
awplus# configure terminal
awplus(config)# ping-poll 45
awplus(config-ping-poll)# normal-interval 60
To reset the interval to the default of 30 seconds for ping-poll instance 45, use the
commands:
awplus# configure terminal
awplus(config)# ping-poll 45
awplus(config-ping-poll)# no normal-interval
Related
Commands
critical-interval
fail-count
ping-poll
sample-size
show ping-poll
timeout (ping polling)
up-count
Parameter Description
<1-65536> Time in seconds between pings when the target is reachable.

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals