C613-50100-01 REV C Command Reference for x930 Series 2842
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
SNMP COMMANDS
SNMP
TRAP LINK-STATUS
snmp trap link-status
Overview Use this command to enable SNMP to send link status notifications (traps) for the
interfaces when an interface goes up (linkUp) or down (linkDown).
Use the no variant of this command to disable the sending of link status
notifications.
Syntax
snmp trap link-status [enterprise]
no snmp trap link-status
Default By default, link status notifications are disabled.
Mode Interface Configuration
Usage The link status notifications can be enabled for the following interface types:
• switch port (e.g. port 1.0.1)
• VLAN (e.g. vlan2)
• static and dynamic link aggregation (e.g. sa2, po2)
To specify where notifications are sent, use the snmp-server host command. To
configure the device globally to send other notifications, use the snmp-server
enable trap command.
Examples To enable SNMP to send link status notifications for ports 1.0.2 to 1.0.6, use
following commands:
awplus# configure terminal
awplus(config)# interface port1.0.2-1.0.6
awplus(config-if)# snmp trap link-status
To enable SNMP to send an Allied Telesis enterprise type of link status notification
for port1.0.1, use following commands:
awplus# configure terminal
awplus(config)# interface 1.0.1
awplus(config-if)# snmp trap link-status enterprise
To disable the sending of link status notifications for port 1.0.2, use following
commands:
awplus# configure terminal
awplus(config)# interface port1.0.2
awplus(config-if)# no snmp trap link-status
Parameter Description
enterprise Send an Allied Telesis enterprise type of link trap.