C613-50100-01 REV C Command Reference for x930 Series 244
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
SYSTEM CONFIGURATION AND MONITORING COMMANDS
CRYPTO
SECURE-MODE
If you wish to leave secure mode, you should delete all sensitive information first.
This means deleting all trustpoints (one by one), then deleting all public/private
key pairs, then turning off secure mode. Use the commands:
awplus# configure terminal
awplus(config)# no crypto pki trustpoint <name>
awplus(config)# crypto key zeroize all
awplus(config)# no crypto secure-mode
awplus(config)# exit
awplus# write
awplus# reboot
The switch must be rebooted after secure mode is turned off, and ideally Flash
memory should be erased via the bootloader.