C613-50100-01 REV C Command Reference for x930 Series 3073
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
SFLOW COMMANDS
SFLOW
MAX-HEADER-SIZE
A similar consideration can be made for an environment using TCP IPv6 over
Ethernet:
Ethernet header (including the 4 byte 802.1Q header component) = 18 bytes
IPv6 header = 40 bytes
TCP header = 24 bytes
Total = 82 bytes
CAUTION: For IPv6, any data existing between 82 bytes and the value set by this
command will be included in the sFlow packet samples. For example, with the
default of 128 applied, up to 128-82=46 bytes of user data could be included in
the sFlow datagram samples sent between the Agent and the Collector.
Note that the agent-to-collector datagrams contain their own UDP headers, which
are outside this calculation.
Example To set the maximum header size to 160 bytes for ports 1.0.1 and 1.0.7, use the
commands:
awplus# configure terminal
awplus(config)# interface port1.0.1,port1.0.7
awplus(config-if)# sflow max-header-size 160
Related
Commands
show running-config sflow
show sflow interface
sflow max-header-size

Table of Contents

Other manuals for Allied Telesis AlliedWare Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus and is the answer not in the manual?

Allied Telesis AlliedWare Plus Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus
CategorySwitch
LanguageEnglish

Related product manuals