C613-50100-01 REV C Command Reference for x930 Series 319
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
PLUGGABLES AND CABLING COMMANDS
SHOW
SYSTEM PLUGGABLE DETAIL
• Power Monitoring: Displays the received power measurement type, which
can be either OMA(Optical Module Amplitude) or Avg(Average Power)
measured in μW.
• TX power monitor support: For QSFP+ modules, this indicates whether the
module supports monitoring of the transmitted optical power level (Yes or
No). If yes, you can view the average output optical power in the output of
the command show system pluggable diagnostics.
NOTE: For parameters that are not supported or not specified, a hyphen is displayed
instead.
Example To display detailed information about the pluggable transceivers installed in a
particular port on the device, use a command like:
awplus# show system pluggable port1.0.25 detail
To display detailed information about all the pluggable transceivers installed on
the device, use the command:
awplus# show system pluggable detail
Output Figure 8-4: Example output from the show system pluggable detail
command for a specific port on a device
awplus#show system pluggable port1.0.25 detail
System Pluggable Information Detail
Port1.0.25
==========
Vendor Name: AGILENT
Device Name: HFCT-5710L
Device Revision: A
Device Type: 1000BASE-LX
Serial Number: 0402142241184360
Manufacturing Datecode: 040214
SFP Laser Wavelength: -
Link Length Supported
Single Mode Fiber : 10Km
OM1 (62.5um) Fiber: 550m
OM2 (50um) Fiber : 550m
Diagnostic Calibration: Internal
Power Monitoring: Avg
FEC BER support: -