C613-50100-01 REV C Command Reference for x930 Series 344
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
LOGGING COMMANDS
LOG
BUFFERED (FILTER)
Default By default the buffered log has a filter to select messages whose severity level is
“notices (5)” or higher. This filter may be removed using the no variant of this
command.
Mode Global Configuration
Examples To add a filter to send all messages generated by EPSR that have a severity of
notices or higher to the buffered log, use the following commands:
awplus# configure terminal
awplus(config)# log buffered level notices program epsr
To add a filter to send all messages containing the text “Bridging initialization” to
the buffered log, use the following commands:
awplus# configure terminal
awplus(config)# log buffered msgtext Bridging initialization
To remove a filter that sends all messages generated by EPSR that have a severity
of notices or higher to the buffered log, use the following commands:
awplus# configure terminal
awplus(config)# no log buffered level notices program epsr
To remove a filter that sends all messages containing the text “Bridging
initialization” to the buffered log, use the following commands:
awplus# configure terminal
awplus(config)# no log buffered msgtext Bridging initialization