C613-50100-01 REV C Command Reference for x930 Series 347
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
LOGGING COMMANDS
LOG
BUFFERED EXCLUDE
Default No log messages are excluded
Mode Global configuration
Example To remove messages that contain the string “example of irrelevant message”, use
the following commands:
awplus# configure terminal
awplus(config)# log buffered exclude msgtext example of
irrelevant message
Related
Commands
clear log buffered
default log buffered
log buffered
log buffered (filter)
log buffered size
show log