C613-50100-01 REV C Command Reference for x930 Series 364
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
LOGGING COMMANDS
LOG
EMAIL TIME
Examples To send messages to the email address test@home.com in the same time zone
as the device’s local time zone, use the following commands:
awplus# configure terminal
awplus(config)# log email admin@base.com time local 0
To send messages to the email address admin@base.com with the time
information converted to the time zone of the email recipient, which is 3 hours
ahead of the device’s local time zone, use the following commands:
awplus# configure terminal
awplus(config)# log email admin@base.com time local-offset plus
3
To send messages to the email address user@remote.com with the time
information converted to the time zone of the email recipient, which is 3 hours
behind the device’s UTC time zone, use the following commands:
awplus# configure terminal
awplus(config)# log email user@remote.com time utc-offset minus
3