C613-50100-01 REV C Command Reference for x930 Series 441
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
INTERFACE TESTING COMMANDS
TEST
INTERFACE
Example To test the switch ports in VLAN 1, install loopbacks in the ports, and enter the
following commands:
awplus(config)# service test
awplus(config)# no spanning-tree rstp enable bridge-forward
awplus(config)# interface vlan1
awplus(config-if)# shutdown
awplus(config-if)# end
awplus# test interface all
To see the output, use the commands:
awplus# show test
awplus# show test count
To start the test on all interfaces for 1 minute use the command:
awplus# test interface all time 1