C613-50100-01 REV C Command Reference for x930 Series 919
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
RIP COMMANDS
TIMERS
(RIP)
To set the update timer to 30, the routing information timeout timer to 180, and
the routing garbage collection timer to 120 with VRF, use the following command:
awplus# configure terminal
awplus(config)# router rip
awplus(config-router)# address-family ipv4 vrf blue
awplus(config-router-af)# timers basic 30 180 120