EasyManuals Logo

Cisco Catalyst 2960 Series User Manual

Cisco Catalyst 2960 Series
2288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1074 background imageLoading...
Page #1074 background image
Configuration Examples for Kerberos
Example: Defining a Kerberos Realm
To define CISCO.COM as the default Kerberos realm, use the following command:
kerberos local-realm CISCO.COM
To tell the device that the CISCO.COM KDC is running on host 10.2.3.4 at port number 170, use the following
Kerberos command:
kerberos server CISCO.COM 10.2.3.4 170
To map the DNS domain cisco.com to the Kerberos realm CISCO.COM, use the following command:
kerberos realm.cisco.com CISCO.COM
Example: Copying a SRVTAB File
To copy over the SRVTAB file on a host named host123.cisco.com for a device named device1.cisco.com,
the command would look like this:
kerberos srvtab remote host123.cisco.com device1.cisco.com-new-srvtab
Example: Configuring Kerberos
This section provides a typical non-Kerberos device configuration and shows output for this configuration
from the write term command, then builds on this configuration by adding optional Kerberos functionality.
Output for each configuration is presented for comparison against the previous configuration.
This example shows how to use the kdb5_edit program to perform the following configuration tasks:
Adding user chet to the Kerberos database
Adding a privileged Kerberos instance of user chet (chet/admin) to the Kerberos database
Adding a restricted instance of chet (chet/restricted) to the Kerberos database
Adding workstation chet-ss20.cisco.com
Adding device chet-2500.cisco.com to the Kerberos database
Adding workstation chet-ss20.cisco.com to the Kerberos database
Extracting SRVTABs for the device and workstations
Listing the contents of the KDC database (with the ldb command)
In this sample configuration, host chet-ss20 is also the KDC:Note
chet-ss20# sbin/kdb5_edit
kdb5_edit: ank chet
Enter password:
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
992
Configuration Examples for Kerberos

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000

Related product manuals