EasyManuals Logo

Cisco Catalyst 2960 Series User Manual

Cisco Catalyst 2960 Series
2288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1187 background imageLoading...
Page #1187 background image
Examples
The following sample output from the show ip ssh command displays the version of SSH that is enabled, the
authentication timeout values, and the number of authentication retries for Version 1 and Version 2 connections:
-----------------------------------------------------------------------
Device# show ip ssh
SSH Enabled - version 1.99
Authentication timeout: 120 secs; Authentication retries: 3
-----------------------------------------------------------------------
The following sample output from the show ip ssh command displays the version of SSH that is enabled, the
authentication timeout values, and the number of authentication retries for a Version 2 connection with no
Version 1 connection:
------------------------------------------------------------------------
Device# show ip ssh
SSH Enabled - version 2.0
Authentication timeout: 120 secs; Authentication retries: 3
------------------------------------------------------------------------
The following sample output from the show ip ssh command displays the version of SSH that is enabled, the
authentication timeout values, and the number of authentication retries for a Version 1 connection with no
Version 2 connection:
------------------------------------------------------------------------
Device# show ip ssh
3d06h: %SYS-5-CONFIG_I: Configured from console by console
SSH Enabled - version 1.5
Authentication timeout: 120 secs; Authentication retries: 3
------------------------------------------------------------------------
Monitoring and Maintaining Secure Shell Version 2
SUMMARY STEPS
1.
enable
2.
debug ip ssh
3.
debug snmp packet
DETAILED STEPS
PurposeCommand or Action
Enables privileged EXEC mode.enable
Step 1
Example:
Device> enable
Enter your password if prompted.
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
1105
How to Configure Secure Shell Version 2 Support

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000