PurposeCommand or Action
(Optional) Saves your entries in the configuration file.copy running-config startup-config
Example:
Switch# copy running-config startup-config
Step 6
Setting Up DNS
If you use the switch IP address as its hostname, the IP address is used and no DNS query occurs. If you
configure a hostname that contains no periods (.), a period followed by the default domain name is appended
to the hostname before the DNS query is made to map the name to an IP address. The default domain name
is the value set by the ip domain-name global configuration command. If there is a period (.) in the hostname,
the Cisco IOS software looks up the IP address without appending any default domain name to the hostname.
Follow these steps to set up your switch to use the DNS:
SUMMARY STEPS
1.
enable
2.
configure terminal
3.
ip domain-name name
4.
ip name-server server-address1 [server-address2 ... server-address6]
5.
ip domain-lookup [nsap | source-interface interface]
6.
end
7.
show running-config
8.
copy running-config startup-config
DETAILED STEPS
PurposeCommand or Action
Enables privileged EXEC mode. Enter your password if prompted.enable
Step 1
Example:
Switch> enable
Enters the global configuration mode.configure terminal
Example:
Switch# configure terminal
Step 2
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
1538
How to Administer the Switch

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000

Related product manuals