(Mandatory) Entry comparison operator used to
compare the current counter value with the entry
value; if true, an event will be raised and event
monitoring will be disabled until exit criteria are met.
entry_op
(Mandatory) Value with which the current counter
value should be compared to decide if the counter
event should be raised.
entry_val
(Mandatory) Exit comparison operator used to
compare the current counter value with the exit value;
if true, event monitoring for this event will be
reenabled.
exit_op
(Mandatory) Value with which the current counter
value should be compared to decide if the exit criteria
are met.
exit_val
(Optional) Priority level at which the script will be
queued:
queue_priority low--Specifies that the script is
to be queued at the lowest of the three priority
levels.
queue_priority normal--Specifies that the script
is to be queued at a priority level greater than
low priority but less than high priority.
queue_priority high--Specifies that the script is
to be queued at the highest of the three priority
levels.
queue_priority last--Specifies that the script is
to be queued at the lowest priority level.
If more than one script is registered with the
"queue_priority_last" argument set, these scripts will
execute in the order in which the events are published.
The queue_priority argument specifies the
queuing priority, but not the execution
priority, of the script being registered.
Note
If this argument is not specified, the default queuing
priority is normal.
queue_priority
(Optional) Maximum run time of the script (specified
in SSSSSSSSSS[.MMM] format, where SSSSSSSSSS
must be an integer representing seconds between 0
and 4294967295, inclusive, and where MMM must
be an integer representing milliseconds between 0
and 999). If this argument is not specified, the default
20-second run-time limit is used.
maxrun
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
1878
event_register_counter

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000