This error means that a control block address that was passed in the EEM API was incorrect.
(_cerr_sub_err = 22) FH_ENULLPTR (event detector internal error - ptr is null)
This error means that an internal EEM event detector pointer was null when it should have contained a value.
(_cerr_sub_err = 25) FH_ESUBSEXCEED (number of subscribers exceeded)
This error means that the number of timer or counter subscribers exceeded the maximum.
(_cerr_sub_err = 26) FH_ESUBSIDXINV (invalid subscriber index)
This error means that the subscriber index was invalid.
(_cerr_sub_err = 54) FH_EFDUNAVAIL (connection to event detector unavailable)
This error means that the event detector was unavailable.
(_cerr_sub_err = 56) FH_EFDCONNERR (event detector connection error)
This error means that the EEM event detector that handles this request is not available.
register_timer
Registers a timer and returns a timer event ID. This Tcl command extension is used by a timer publisher to
perform this registration before using the event ID to manipulate the timer if it does not use the
event_register_timer command extension to register as a publisher and subscriber.
Syntax
register_timer watchdog|countdown|absolute|cron name ?
Arguments
(Mandatory) The name of the timer to be manipulated.name
Result String
event_id %u
Where event_id is the timer event ID for the specified timer (can be used to manipulate the timer by the
timer_arm or timer_cancel command extensions).
Set _cerrno
Yes
(_cerr_sub_err = 2) FH_ESYSERR (generic/unknown error from OS/system)
This error means that the operating system reported an error. The POSIX errno value that is reported with the
error should be used to determine the cause of the operating system error.
(_cerr_sub_err = 4) FH_EINITONCE (Init() is not yet done, or done twice.)
This error means that the request to register the specific event was made before the EEM event detector had
completed its initialization.
(_cerr_sub_err = 6) FH_EBADEVENTTYPE (unknown EEM event type)
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
2016
register_timer

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000