Configuring OBFL
We recommend that you do not disable OBFL and that you do not remove the data stored in the flash
memory.
Caution
•
To enable OBFL, use the hw-switch switch [switch-number] logging onboard [message level level]
global configuration command. On switches, the range for switch-number is from 1 to 9. Use the message
level level parameter to specify the severity of the hardware-related messages that the switch generates
and stores in the flash memory.
•
To copy the OBFL data to the local network or a specific file system, use the copy onboard switch
switch-number url url-destination privileged EXEC command.
•
To disable OBFL, use the no hw-switch switch [switch-number] logging onboard [message level]
global configuration command.
•
To clear all the OBFL data in the flash memory except for the uptime and CLI command information,
use the clear onboard switch switch-number privileged EXEC command.
•
In a switch stack, you can enable OBFL on a standalone switch or on all stack members by using the
hw-switch switch [switch-number] logging onboard [message level level] global configuration command.
•
You can enable or disable OBFL on a member switch from the active switchstack master.
For more information about the commands in this section, see the command reference for this release.
Related Topics
Onboard Failure Logging on the Switch, on page 1630
Displaying OBFL Information
Verifying Troubleshooting of the Software Configuration
Displaying OBFL Information
Table 150: Commands for Displaying OBFL Information
PurposeCommand
Displays the OBFL CLI
commands that were entered
on a standalone switch or the
specified stack members.
show logging onboard [module[switch-number ]]clilog
Switch# show logging onboard 1 clilog
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
1646