PurposeCommand or Action
Example:
Switch(config)# snmp-server user Pat
public v2c
Configures an SNMP group.
snmp-server group group-name {v1 | v2c | v3
{auth | noauth | priv}} [read readview] [write
writeview] [notify notifyview] [access access-list]
Step 5
Example:
Switch(config)# snmp-server group public
v2c access lmnop
Specifies the recipient of an SNMP trap operation.
snmp-server host host-addr [informs | traps]
[version {1 | 2c | 3 {auth | noauth | priv}}]
community-string [notification-type]
Step 6
For host-addr, specify the name or Internet address of the host (the
targeted recipient).
Example:
Switch(config)# snmp-server host
203.0.113.1 comaccess snmp
(Optional) Specify traps (the default) to send SNMP traps to the
host.
(Optional) Specify informs to send SNMP informs to the host.
(Optional) Specify the SNMP version (1, 2c, or 3). SNMPv1 does
not support informs.
(Optional) For Version 3, select authentication level auth, noauth,
or priv.
The priv keyword is available only when the cryptographic
software image is installed.
Note
For community-string, when version 1 or version 2c is specified,
enter the password-like community string sent with the notification
operation. When version 3 is specified, enter the SNMPv3 username.
The @ symbol is used for delimiting the context information. Avoid
using the @ symbol as part of the SNMP community string when
configuring this command.
(Optional) For notification-type, use the keywords listed in the table
above. If no type is specified, all notifications are sent.
Enables the switch to send traps or informs and specifies the type of
notifications to be sent. For a list of notification types, see the table
above, or enter snmp-server enable traps ?
snmp-server enable traps notification-types
Example:
Switch(config)# snmp-server enable traps
snmp
Step 7
To enable multiple types of traps, you must enter a separate
snmp-server enable traps command for each trap type.
When you configure a trap by using the notification type
port-security, configure the port security trap first, and
then configure the port security trap rate:
Note
1
snmp-server enable traps port-security
2
snmp-server enable traps port-security trap-rate rate
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
462
How to Configure SNMP

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000

Related product manuals