Wired Location Service
The switch uses the location service feature to send location and attachment tracking information for its
connected devices to a Cisco Mobility Services Engine (MSE). The tracked device can be a wireless endpoint,
a wired endpoint, or a wired switch or controller. The switch notifies the MSE of device link up and link down
events through the Network Mobility Services Protocol (NMSP) location and attachment notifications.
The MSE starts the NMSP connection to the switch, which opens a server port. When the MSE connects to
the switch there are a set of message exchanges to establish version compatibility and service exchange
information followed by location information synchronization. After connection, the switch periodically sends
location and attachment notifications to the MSE. Any link up or link down events detected during an interval
are aggregated and sent at the end of the interval.
When the switch determines the presence or absence of a device on a link-up or link-down event, it obtains
the client-specific information such as the MAC address, IP address, and username. If the client is LLDP-MED-
or CDP-capable, the switch obtains the serial number and UDI through the LLDP-MED location TLV or
CDP.
Depending on the device capabilities, the switch obtains this client information at link up:
Slot and port specified in port connection
MAC address specified in the client MAC address
IP address specified in port connection
802.1X username if applicable
Device category is specified as a wired station
State is specified as new
Serial number, UDI
Model number
Time in seconds since the switch detected the association
Depending on the device capabilities, the switch obtains this client information at link down:
Slot and port that was disconnected
MAC address
IP address
802.1X username if applicable
Device category is specified as a wired station
State is specified as delete
Serial number, UDI
Time in seconds since the switch detected the disassociation
When the switch shuts down, it sends an attachment notification with the state delete and the IP address before
closing the NMSP connection to the MSE. The MSE interprets this notification as disassociation for all the
wired clients associated with the switch.
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
60
LLDP, LLDP-MED, and Wired Location Service Overview

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000