This is an example of output for the show vmps privileged EXEC command:
Switch# show vmps
VQP Client Status:
--------------------
VMPS VQP Version: 1
Reconfirm Interval: 60 min
Server Retry Count: 3
VMPS domain server: 172.20.128.86 (primary, current)
172.20.128.87
Reconfirmation status
---------------------
VMPS Action: other
Configuration Example for VMPS
Example: VMPS Configuration
This network has a VMPS server switch and VMPS client switches with dynamic-access ports with this
configuration:
The VMPS server and the VMPS client are separate switches.
The Catalyst 6500 series Switch A is the primary VMPS server.
The Catalyst 6500 series Switch C and Switch J are secondary VMPS servers.
End stations are connected to the clients, Switch B and Switch I.
The database configuration file is stored on the TFTP server with the IP address 172.20.22.7.
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
2162
Configuration Example for VMPS

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000

Related product manuals