(Optional) The time period during which the CLI
event detector waits for the policy to exit (specified
in SSSSSSSSSS[.MMM] format, where SSSSSSSSSS
must be an integer representing seconds between 0
and 4294967295, inclusive, and where MMM must
be an integer representing milliseconds between 0
and 999). If the default time period expires before the
policy exits, the default action will be executed. The
default action is to run the command. If this argument
is not specified, the default time period is set to 30
seconds.
default
Result String
None
Set _cerrno
No
Event_reqinfo
"event_id %u event_type %u event_type_string {%s} event_pub_sec %u event_pub_msec %u
arg %u"
DescriptionEvent Type
Unique number that indicates the ID for this published
event. Multiple policies may be run for the same
event, and each policy will have the same event_id.
event_id
Type of event.event_type
An ASCII string that represents the name of the event
for this event type.
event_type_string
The time, in seconds and milliseconds, when the event
was published to the EEM.
event_pub_sec event_pub_msec
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
1932
event_register_rpc

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000

Related product manuals