Incremental (Partial) Configuration
After the network is running, new services can be added by using the Cisco IOS CNS agent. Incremental
(partial) configurations can be sent to the switch. The actual configuration can be sent as an event payload by
way of the event gateway (push operation) or as a signal event that triggers the switch to initiate a pull operation.
The switch can check the syntax of the configuration before applying it. If the syntax is correct, the switch
applies the incremental configuration and publishes an event that signals success to the configuration server.
If the switch does not apply the incremental configuration, it publishes an event showing an error status. When
the switch has applied the incremental configuration, it can write it to nonvolatile random-access memory
(NVRAM) or wait until signaled to do so.
Related Topics
Enabling a Partial Configuration for Cisco IOS CNS Agent, on page 425
Monitoring CNS Configurations, on page 427
Synchronized Configuration
When the switch receives a configuration, it can defer application of the configuration upon receipt of a
write-signal event. The write-signal event tells the switch not to save the updated configuration into its
NVRAM. The switch uses the updated configuration as its running configuration. This ensures that the switch
configuration is synchronized with other network activities before saving the configuration in NVRAM for
use at the next reboot.
Automated CNS Configuration
To enable automated CNS configuration of the switch, you must first complete the prerequisites listed in this
topic. When you complete them, power on the switch. At the setup prompt, do nothing; the switch begins the
initial configuration. When the full configuration file is loaded on your switch, you do not need to do anything
else.
For more information on what happens during initial configuration, see "Related Topics."
Table 43: Prerequisites for Enabling Automatic Configuration
Required ConfigurationDevice
Factory default (no configuration file)Access switch
IP helper address
Enable DHCP relay agent
2
IP routing (if used as default gateway)
Distribution switch
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
413
Information About Configuring the Configuration Engine

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000