EasyManuals Logo

Cisco Catalyst 2960 Series User Manual

Cisco Catalyst 2960 Series
2288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #791 background imageLoading...
Page #791 background image
DETAILED STEPS
PurposeCommand or Action
Enables privileged EXEC mode. Enter your password if
prompted.
enable
Example:
Switch> enable
Step 1
Enters the global configuration mode.configure terminal
Example:
Switch# configure terminal
Step 2
Defines an IPv6 source-guard policy name and enters switch
integrated security features source-guard policy
configuration mode.
[no] ipv6 source-guard policy source-guard-policy
Example:
Switch (config)# ipv6 source-guard policy
my_snooping_policy
Step 3
Disables the validate address feature and enables the IPv6
prefix guard feature to be configured.
[ no ] validate address
Example:
Switch (config-sisf-sourceguard)# no validate
address
Step 4
Enables IPv6 source guard to perform the IPv6 prefix-guard
operation.
validate prefix
Example:
Switch (config-sisf-sourceguard)# validate
prefix
Step 5
Exits switch integrated security features source-guard policy
configuration mode and returns to privileged EXEC mode.
exit
Example:
Switch (config-sisf-sourceguard)# exit
Step 6
Displays the IPv6 source-guard policy configuration.
show ipv6 source-guard policy [source-guard-policy]
Example:
Switch # show ipv6 source-guard policy policy1
Step 7
Related Topics
Information about First Hop Security in IPv6, on page 678
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
709
How to Configure IPv6 Prefix Guard

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000