EasyManuals Logo

Cisco Catalyst 2960 Series User Manual

Cisco Catalyst 2960 Series
2288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1743 background imageLoading...
Page #1743 background image
Embedded Event Manager 1.0
EEM 1.0 introduced the following event detectors:
SNMPThe Simple Network Management Protocol (SNMP) event detector allows a standard SNMP
MIB object to be monitored and an event to be generated when the object matches specified values or
crosses specified thresholds.
SyslogThe syslog event detector allows for screening syslog messages for a regular expression pattern
match.
EEM 1.0 introduced the following actions:
Generating prioritized syslog messages.
Generating a Cisco Networking Services (CNS) event for upstream processing by CNS devices.
Reloading the Cisco software.
Switching to a secondary processor in a fully redundant hardware configuration.
Embedded Event Manager 2.0
EEM 2.0 introduced some new features. EEM 2.0 introduced the following event detectors:
Application-SpecificThe application-specific event detector allows any Embedded Event Manager
policy to publish an event.
CounterThe counter event detector publishes an event when a named counter crosses a specified
threshold.
Interface CounterThe interface counter event detector publishes an event when a generic Cisco IOS
interface counter for a specified interface crosses a defined threshold.
TimerThe timer event detector publishes events for the following four different types of timers:
absolute-time-of-day, countdown, watchdog, and CRON.
Watchdog System Monitor (IOSWDSysMon)The Cisco IOS watchdog system monitor event detector
publishes an event when CPU or memory utilization for a Cisco IOS process crosses a threshold.
EEM 2.0 introduced the following actions:
Setting or modifying a named counter.
Publishing an application-specific event
Generating an SNMP trap.
The ability to run a Cisco defined sample policy written using Tool Command Language (Tcl) was introduced.
A sample policy was provided that could be stored in the system policy directory.
Embedded Event Manager 2.1
EEM 2.1 introduced the following new event detectors:
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
1661
Information About Embedded Event Manager

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000