DETAILED STEPS
PurposeCommand or Action
Enables privileged EXEC mode.enable
Step 1
Example:
Device> enable
Enter your password if prompted.
Enters global configuration mode.configure terminal
Example:
Device# configure terminal
Step 2
Registers the applet with the EEM and enters applet
configuration mode.
event manager applet applet-name
Example:
Device(config)# event manager applet action
Step 3
Specifies that an EEM policy is to be registered with the EEM
and can be run manually.
event none
Example:
Device(config-applet)# event none
Step 4
Gets input from the local console in a synchronous applet and
stores the value in the given variable when an EEM applet is
triggered.
action label gets variable
Example:
Device(config-applet)# action label2 gets
input
Step 5
Specifies the action to be taken when an EEM applet is
triggered.
action label syslog [priority priority-level] msg
msg-text
Step 6
Example:
Device(config-applet)# action label3 syslog
msg Input entered was \$input\“”
In this example, the action to be taken is to write the
value of the variable specified in Step 5, to syslog.
Exits applet configuration mode and returns to privileged
EXEC mode.
exit
Example:
Device(config-applet)# exit
Step 7
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
1721
How to Write EEM Policies Using the Cisco IOS CLI

Table of Contents

Other manuals for Cisco Catalyst 2960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2960 Series and is the answer not in the manual?

Cisco Catalyst 2960 Series Specifications

General IconGeneral
LayerLayer 2
Power over Ethernet (PoE)Available on some models
RAM128 MB
Flash Memory32 MB
MAC Address Table Size8000
Operating Temperature0°C to 45°C (32 to 113°F)
Ports24 or 48 x 10/100/1000

Related product manuals